Technical Specifications
| AC Power | 5kW - 10kW |
|---|---|
| Inverter Type | Гибридный инвертор |
| MPP Voltage Range | 180 – 900 Volt |
| MPP Tracker | 2 |
| Phases | 3 |
| Коммуникация | CAN, RS485, RS232, Wi-Fi, Ethernet, 4G (optional) |
| Pieces per Package | 1 per carton, 12 per pallet |
| Гарантия | 5 years (extendable up to 20 years) |
Product Description
SAJ H2 5 – 10 kW Three-Phase Hybrid Inverter (T2)
High-voltage hybrid inverter that pairs 150 % DC oversizing with
98 % peak efficiency. It delivers seamless <10 ms UPS backup,
30 A charge/discharge and supports 100 % phase imbalance—perfect for
commercial villas and small businesses seeking maximum self-consumption.
Design
| Size | 433 × 549 × 207 mm |
| Weight | 25 kg |
| Cooling | Fan-less natural convection < 30 dB |
| Enclosure | Aluminium, IP 65 |
PV & AC Specs
| Rated AC Power | 5 / 6 / 8 / 10 kW |
| Max PV Power | 7.5 – 15 kW DC (150 %) |
| MPPT Trackers / Strings | 2 × 1 (180–900 V, 15 A ea.) |
| Grid Output | 3L + N + PE, 220/380 – 230/400 V |
| UPS Backup | 5 – 10 kVA, switch < 10 ms |
| Максимальная эффективность | 98 % |
| AC Overload | 110 % for 60 s |
Battery Specs
| Chemistry | HV Li-ion (180–600 V) |
| Charge / Discharge | 30 A max (all models) |
| Round-trip η | 97.6 % |
| Fast Charge | 100 % power in 2 hrs |
Smart Functions
- Four modes: Self-Use, TOU, Backup, Peak-shaving
- Zero-export & dynamic limit via smart meter
- 100 % three-phase imbalance capability
- Необязательный AFCI 15 A for arc-fault shutdown
- Bluetooth LCD + app; Wi-Fi / Ethernet / 4G cloud & OTA
Safety & Compliance
- DC switch, Type III SPDs, RCMU, GFCI, DCI & insulation monitoring
- Anti-islanding, AC short-circuit & overload protection
- Meets CEI 0-21, EN 50549, VDE-AR-N 4105, AS 4777.2, G98/G99
Install & Service
- Wall-mount bracket, MC4 PV inputs, quick-fit AC & battery plugs
- Ground-fault alarm & CT-based export monitor
- Commission in minutes via eSAJ Home app
- Global SAJ service network
Гарантия
| Standard Cover | 5 years |
| Extension Options | 10 / 15 / 20 years |
Product Resources
Download the latest user manual & datasheet:
Product Video Showcase
Watch our product demonstrations and tutorials
SAJ's beautiful and stunning case reference in Sweden - 2023 - EN
Video failed to load
SAJ H2&B2 Installation tutorials
Video failed to load
SAJ New Generation H2& B2 Series Meeting You in Intersolar South America
Video failed to load
SAJ InterSolar Europe 2022
Video failed to load
Application Scenarios
Discover how this product can be used in different real-world scenarios
Small Commercial Rooftop (Clinic / Store / Workshop)
Who it’s for: Small clinics, retail stores, and light workshops needing 3-phase power, backup for POS/IT, and bill savings via TOU.
| Component | Recommended | Why |
|---|---|---|
| PV array | 6–10 kW (2 MPPT, split E/W or S) | Smooths peaks, better yield on mixed roofs |
| Battery (HV) | 10–15 kWh, CAN/RS485 BMS | Covers evening peak + short outages |
| Backup bus | POS, lighting, router, CCTV | Avoid high inrush devices on backup |
3-phase balance checklist:
- Distribute single-phase loads across L1/L2/L3 to reduce imbalance
- Keep backup branch light and stable (IT + lights first)
- Verify CT orientation before enabling zero-export
“Two brownouts in a week—POS never dropped once.” — Store owner feedback
Suburban Villa with Heat Pump / Pool Pump (3-Phase Loads)
Who it’s for: Homes with 3-phase appliances (heat pump, pool pump, large induction cooktop) that want comfort + lower bills.
Suggested setup:
- PV 7–10 kW across 2 MPPT (keep string Isc ≤ inverter limit)
- Battery 10–15 kWh; reserve SOC 25–30% for outage buffer
- Zero-export ON if your HOA/utility forbids feed-in
Simple TOU plan (code style):
Charge (off-peak): 00:00–05:00 Discharge (peak): 18:00–22:00 Reserve SOC: 25% Zero-export: 08:00–18:00 (if required)
Installer notes:
- Place EV charger and heat pump on non-backup side to avoid inrush during transfer
- Balance single-phase sub-circuits across L1/L2/L3
- Save screenshots of final parameters for utility file
Rural Farm: Cold Room + Water Pump + Night Lighting
Who it’s for: Farms with 3-phase pump during the day and cold room/light loads at night, where outages or voltage dips happen.
| Time | Energy flow | Note |
|---|---|---|
| Day (sunny) | PV → Pump + surplus → Battery | Pump on non-backup side; monitor inrush |
| Evening | Battery → Cold room + lights | Quiet hybrid, no genset noise |
| Outage | UPS ≤10 ms keeps lighting/IT stable | Avoid starting pump during transfer |
Wiring quick path:
- CT on main incomer (arrow → grid) for export control
- Cold room and lights on backup; pump on grid/non-backup
- Set TOU to recharge off-peak if night cooling is heavy
How We Work With You
From your first call to final delivery, we make the process simple and clear
Talk & Plan
We listen to your needs and create a plan that works for you. Our team will help you understand all your options.
Quote & Agree
You get a clear price with no hidden costs. Once you're happy with everything, we sign the agreement and start working.
Make & Check
We carefully make your order and check everything meets our high standards. You'll know exactly how things are going.
Ship & Support
Your order ships safely to you on time. We're always here to help if you need anything after delivery.
Frequently Asked Questions
Find answers to common questions about our products and services
What are the core electrical specs and grid compliance?
Specs at a glance
| Item | 5k | 6k | 8k | 10k |
|---|---|---|---|---|
| Rated AC power | 5 000 Вт | 6,000 W | 8,000 W | 10 000 Вт |
| PV voltage / MPPT range | 1000 V max / 180–900 V | |||
| Strings / MPPT | 2 MPPTs, 1 string per MPPT; 15 A per string (Isc 18 A) | |||
| Battery (HV) | Lithium, 180–600 V; charge/discharge 30 A | |||
| Эффективность | Max 98.0% (Euro 97.6%) | |||
| IP / Noise / Cooling | IP65 / <30 dBA / natural convection | |||
- Supports 150% DC oversizing and 110% AC overloading (project-dependent).
- Three-phase grids: 220/380 V, 230/400 V, 3L/N/PE; PF 0.8 lead–lag; THD(i) <3%.
How does backup (UPS) behave and what should go on the backup circuit?
Suggested “essential loads” (example):
| Load | Power | Notes |
|---|---|---|
| LED lighting | 100–300 W | Primary rooms / signage |
| Router + CCTV | 30–60 W | Network continuity |
| Fridge (inverter type) | 90–150 W avg | Exclude large compressors |
3-step setup:
- Wire essential loads to the BACK-UP terminals; keep heavy inrush loads off this bus.
- Set a reserve SOC (e.g., 25–30%) so evening outages still have cover.
- Run a grid-off test and confirm transfer sequence in the LED/app.
How should I size PV strings and the high-voltage battery?
PV inputs: 2 × MPPT, 1 string/MPPT, 15 A per string (Isc limit 18 A); MPPT window 180–900 V; DC max 1000 V.
Battery (HV): Lithium 180–600 V; charge/discharge 30 A. Match a BMS with CAN/RS485 so SOC is accurate and charge curves are safe.
| Design feature | Why it matters |
|---|---|
| 150% DC oversizing | Smoother output on cloudy days; better early/late harvest |
| 110% AC overloading | Short peak handling without clipping alarms |
Example string count: Panel Voc(stc)=49 V, TempCoeffVoc=-0.28%/°C, Tmin=-10°C Voc(@-10°C)=49×[1+0.0028×(25-(-10))]≈53.8 V Max series count ≈ floor(1000/53.8)=18 modules per string
Can I enforce zero-export? How should the meter/CT be wired?
Yes. Use the SAJ-recommended smart meter + CTs and enable Export Limit in the eSAJ Home app.
Wiring quick path:
- CT arrow faces the grid on the incoming main.
- Connect meter to EMS/METER port via RS485 using pin 1 (A1+) and pin 2 (B1-).
- If cable > 20 m, add a 120 Ω resistor on the meter as specified.
- In app: set Export Limit = 0 W (or your cap), verify live readings.
Common mistakes to avoid:
- Reversed CT → negative readings (flip orientation).
- RS485 A/B swapped → no data (swap A/B).
- Multiple devices on bus without unique addresses.
How do I commission and monitor (app, reports, power quality modes)?
Commissioning steps (quick):
- Install eSAJ Home; select “Overseas Node”; bind device by SN via Bluetooth.
- Pick country/grid profile; confirm frequency & voltage range.
- Run Export-Limit wizard (if required) and save parameters.
Power quality & control: Fixed PF, fixed Q, Volt-Watt and Volt-Var modes per AS/NZS 4777.2; PF 0.8 lead–lag; THD(i) <3%.
Simple TOU plan (example): Charge: 00:00–05:00 (off-peak) Discharge: 18:00–22:00 (peak) Reserve SOC: 25% Zero-export: Enabled daytime if policy requires
What arrives in the box (hardware & documents) and how do I use them?
Everything needed to mount, wire, and commission quickly:
| Item | What it’s for |
|---|---|
| Hybrid inverter unit | Core PV+Battery control |
| Mounting bracket, bolts, anchors, gaskets | Secure wall mount |
| PV connectors, battery plugs, plug-in AC connectors | Clean, tool-guided terminations |
| Smart meter + CTs (3) | Export-limit, energy stats |
| Communication module (Wi-Fi/4G) | Cloud monitoring |
| 120 Ω resistor, protective covers | Long RS485 runs; outdoor seals |
| Quick Installation Guide + User Manual (PDF/print) | Wiring, setup, safety & compliance |
Before you start:
- Confirm grid profile and breaker size (32 A typical per manual).
- Check CT orientation; set meter address; keep RS485 under 20 m or add 120 Ω as directed.
- Scan QR to get the latest manual/cert PDFs for your utility filing.
Still have questions?
Can't find the answer you're looking for? Our support team is here to help you.
Related Products
Discover similar products that might interest you
Ready to Talk About This Product?
Tell us what you need—from pricing and availability to technical specs or project planning. Our product team will respond within 24 hours.
- Request tailored quotations and lead times
- Get engineering support and compatibility checks
- Receive product literature and case studies
Спасибо! Мы получили ваш запрос.
Our product specialists will reach out within 24 hours. A detailed Thank You page has opened in a new tab.