Onduleur hybride monophasé basse tension H2-5k~12k
Technical Specifications
| AC Power | 5kW - 12kW |
|---|---|
| Inverter Type | Onduleur hybride |
| MPP Voltage Range | 90 – 480 Volt |
| MPP Tracker | 2 |
| Phases | 1 |
| Communication | RS485, RS232, CAN, Wi-Fi, Ethernet, 4G |
| Pieces per Package | 1 per carton, 10 per pallet |
| Garantie | 5 years (extendable to 10 years) |
Product Description
SAJ H2 5 – 12 kW Low-Voltage Hybrid Inverter (LS2)
Single-phase hybrid inverter for entry-level storage markets.
20 A string current, 200 % DC oversizing and dual-MPPT architecture harvest more power while a built-in meter enables zero-export control. Up to four units can run in parallel, delivering seamless 20 ms UPS backup, generator charging and smart-load management – all in a compact 29 kg IP65 chassis.
Design
| Size | 590 × 380 × 241 mm |
| Weight | 29 kg |
| Cooling | Intelligent fan < 50 dB |
| Enclosure | Aluminium, IP 65 |
PV & AC Specs
| Rated AC Power | 5 / 6 / 7.6 / 8 / 10 / 12 kW |
| Max PV Power | 10 – 24 kW DC (200 %) |
| MPPT Trackers / Strings | 2 × 1 (90 – 480 V, 20 A ea.) |
| Grid Output | L N PE, 220/230/240 V |
| UPS Backup | 5 – 12 kVA, < 20 ms transfer |
| Efficacité maximale | 97.6 % |
| THD (grid) | < 3 % |
Battery Specs
| Chimie | 48 V Lead-acid or LiFePO4 |
| Voltage Range | 40 – 60 V |
| Max Charge / Discharge | 100 A (5 – 8 kW) / 120 A (10 – 12 kW) |
| Round-trip η | up to 96.6 % |
Smart Functions
- Self-Use, TOU, Backup & Generator/Smart-Load modes
- Built-in meter for zero-export & CT limit control
- Parallel up to 4 units on-grid or off-grid
- AFCI (optional) & rapid shutdown ready
- Bluetooth LCD + Elekeeper app; Wi-Fi / Ethernet / 4G cloud & OTA updates
Safety & Compliance
- DC switch, Type II AC & DC SPDs, RCMU, GFCI & DCI
- Active anti-islanding, AC short-circuit & overload protection
- Certified to EN 62109-1/2, AS 4777.2, VDE-AR-N 4105, CEI 0-21 and more
Install & Service
- Wall-mount bracket, terminal-block PV / AC / battery
- Smart-meter & CTs included; parallel & generator terminals onboard
- Commission in minutes via Elekeeper app
- Global SAJ service network
Garantie
| Standard Cover | 5 years |
| Extension Options | 10 ans |
Product Resources
Download the latest user manual & datasheet:
Product Video Showcase
Watch our product demonstrations and tutorials
SAJ H2 5-12k LS2 Open inside
Video failed to load
SAJ Next-Generation H2 LV Hybrid Inverter
Video failed to load
SAJ H2 5-12k LS2 Battery parameters setting
Video failed to load
SAJ H2 5-12k LS2 Grid standard setting
Video failed to load
SAJ H2 5-12k LS2 B3+H2LV installation
Video failed to load
SAJ's beautiful and stunning case reference in Sweden - 2023 - EN
Video failed to load
Application Scenarios
Discover how this product can be used in different real-world scenarios
Urban Home Office: Quiet Backup for Work & Study
Who it’s for: Apartments or townhouses that need a silent backup for laptops, Wi-Fi, lights, and a fridge while working from home.
Suggested backup pack (example):
| Load | Puissance | Hours/day |
|---|---|---|
| LED lighting (2–4 rooms) | 120–200 W | 4–6 h |
| Wi-Fi router + CCTV | 25–45 W | 24 h |
| Laptop / small PC | 60–120 W | 6–10 h |
| Fridge (inverter type) | 90–150 W avg | 24 h (duty) |
3 quick steps:
- Move essential sockets to the BACK-UP sub-circuit; label clearly.
- Set a reserve SOC (e.g., 25–30%) so evening outages still have power.
- Run a 2-minute outage test; confirm seamless transfer and load order.
“Power blinked during a call—laptop and Wi-Fi stayed up. No interruption.” — Home worker feedback
Suburban House with TOU Tariffs: Cut Bills with Simple Scheduling
Who it’s for: Detached houses with 5–10 kW PV looking to shift energy from cheap night rates to the evening peak.
How savings happen (simple plan):
Charge (off-peak): 00:00–05:00 Daytime: PV → House; surplus → Battery Discharge (peak): 18:00–22:00 Reserve SOC: 25–30%
- 2 MPPTs handle east/west or south split roofs cleanly.
- Use the app to adjust times each season as daylight shifts.
- Keep heavy appliances (oven, large compressor) on non-backup.
| Component | Recommended | Reason |
|---|---|---|
| PV array | 5–10 kW | Covers daytime base load + charges battery |
| Battery | 8–15 kWh | 2–4 h peak shaving |
| Mode | Self-Use + TOU | Automated schedule; easy to tweak |
Small Retail / Clinic (Single-Phase): Keep Sales & IT Online
Who it’s for: Street-level shops, clinics, or cafés that run POS, lights, a small fridge, and basic IT—wanting steady service during short grid issues.
Recommended kit:
- PV 6–10 kW split across 2 MPPTs (east/west or south split)
- Battery 10–16 kWh for evening hours
- Backup branch: POS, lighting, router/CCTV, small freezer
Energy flow (typical day):
| Time block | Flow | Note |
|---|---|---|
| Morning–Afternoon | PV → Loads; surplus → Battery | Covers base load while open |
| Evening | Battery → POS, lights, IT | Smooth checkout during peak |
| Outage | Seamless backup output | No reboot on POS/router |
Quick continuity checklist:
- Label backup vs non-backup circuits at the board.
- Keep high inrush appliances (big compressor, ovens) on non-backup.
- Run a 10-minute test with the site open; check card terminals and printers.
“Short brownout—POS never dropped, customers didn’t notice.” — Store owner
How We Work With You
From your first call to final delivery, we make the process simple and clear
Talk & Plan
We listen to your needs and create a plan that works for you. Our team will help you understand all your options.
Quote & Agree
You get a clear price with no hidden costs. Once you're happy with everything, we sign the agreement and start working.
Make & Check
We carefully make your order and check everything meets our high standards. You'll know exactly how things are going.
Ship & Support
Your order ships safely to you on time. We're always here to help if you need anything after delivery.
Foire aux questions
Find answers to common questions about our products and services
How do I choose between 5k, 6k, 7.6k, 8k, 10k, and 12k for my site?
Quick idea: pick by daytime peak load + roof PV space; size battery by evening use hours.
| Site type | Peak load | Inverter | PV (typ.) | Battery (2–4 h) |
|---|---|---|---|---|
| Home + home office | 3–6 kW | 5–6 kW | 5–8 kW | 7–12 kWh |
| Villa / small shop | 6–10 kW | 7.6–10 kW | 8–12 kW | 10–20 kWh |
| Clinic / café with IT | 8–12 kW | 10–12 kW | 10–16 kW | 12–24 kWh |
Checklist before you lock size:
- List 5 critical loads you want alive in outages (backup branch).
- Count roof strings for 2 MPPT distribution; keep within 500 V DC max and current limits per model. :contentReference[oaicite:1]{index=1}
- Confirm local grid profile and breaker size (see FAQ 5 table).
What’s in the box, and which documents will I receive?
Typical package (by model):
| Item | Use |
|---|---|
| Hybrid inverter | PV + battery controller |
| Communication module (Wi-Fi/4G) | App/portal connectivity |
| CT (external) | Metering & energy flow sensing |
| Terminal kit, battery temp sensor | Clean wiring / lead-acid temp comp. |
| Mounting hardware + hole template | Fast wall install |
| Documents pack | Quick Guide, User Manual, Warranty |
Sunriver Electric supplies the latest digital PDFs (datasheet, quick guide, user manual) on request to speed up approvals and site prep. :contentReference[oaicite:2]{index=2}
Before installation:
- Inspect carton for damage; verify exact model on the label.
- Lay out connectors separately to avoid cross-wiring.
- Read safety notes; install only by qualified electricians.
Tip: keep the hole-positioning paper; it speeds drilling and keeps clearances correct for cable entry. :contentReference[oaicite:3]{index=3}
What batteries can I use, and how big should the pack be?
Battery types: LiFePO₄ or lead-acid, low voltage 40–60 V. Use BMS CAN/RS485 mapping for lithium; connect the temp sensor for lead-acid. :contentReference[oaicite:4]{index=4} :contentReference[oaicite:5]{index=5}
Simple sizing (examples):
| Use case | Evening load | Battery (kWh) |
|---|---|---|
| Home + fridge + IT | 1.5–2.5 kW × 3 h | 6–8 |
| Villa / small shop | 2–4 kW × 3–4 h | 10–16 |
| IT-heavy home office | 1–2 kW × 6 h | 8–12 |
Connection notes:
- Use the correct battery cable size (up to 0 AWG on 10 kW); torque to spec. :contentReference[oaicite:7]{index=7}
- Insert via BAT gland to BAT+/BAT− terminals; add isolator ≥70 A if required by local code. :contentReference[oaicite:8]{index=8}
- For lithium, wire BMS to BMS_CAN; for lead-acid, connect the temp sensor to COM1. :contentReference[oaicite:9]{index=9}
How does backup work, and what should go on the backup branch?
The inverter switches to battery and keeps critical loads running immediately and seamlessly during a grid outage. This avoids flicker or reboots on essential circuits. :contentReference[oaicite:10]{index=10}
Put on BACK-UP: LED lighting, router/CCTV, laptops/PCs, fridge (inverter type).
Keep on non-backup: EV charger, large ovens, big compressor motors (inrush current). :contentReference[oaicite:11]{index=11}
| Mode | AC output (backup) | THDv |
|---|---|---|
| H2-5–12k LS2 | up to rated VA, 60 s peak headroom | <3% (linear load) |
Use the separate BACK-UP terminals shown in the junction box; label the backup sub-board clearly. :contentReference[oaicite:12]{index=12}
What AC breaker and cable sizes should I prepare (by model)?
Grid-side breaker & cable (from Quick Guide):
| Modèle | AC breaker | Cable size (L/N) |
|---|---|---|
| H2-5K-LS2 | 50 A | 8 AWG |
| H2-6K-LS2 | 63 A | 8 AWG |
| H2-7.6/8K-LS2 | 80 A | 8 AWG |
| H2-10K-LS2 | 100 A | 6 AWG |
Notes:
- Keep total voltage drop ≤2% from point of grid connection; upsize cable if the run is long.
- Strip lengths: 20 mm for LOAD/GRID, 10 mm for GEN; torque to the listed values in the guide. :contentReference[oaicite:13]{index=13}
- Follow local codes for breaker curves and RCD selection.
How do I commission and monitor with the Elekeeper app?
- Download Elekeeper (iOS/Android). Choose language and Overseas Node; register if needed. :contentReference[oaicite:14]{index=14}
- Local connect via Bluetooth → select inverter SN → run the Initialization wizard. :contentReference[oaicite:15]{index=15}
- Set battery brand/mode, wiring (with/without meter/CT), and country/grid compliance profile. :contentReference[oaicite:16]{index=16}
- Join Wi-Fi/Ethernet/4G for remote monitoring; create the plant for the owner. :contentReference[oaicite:17]{index=17}
Simple TOU schedule (example):
Charge (off-peak): 00:00–05:00 Discharge (peak): 18:00–22:00 Reserve SOC: 25–30%
If Italy: run the built-in CEI 0-21 self-test and save the report from the app. :contentReference[oaicite:19]{index=19}
Still have questions?
Can't find the answer you're looking for? Our support team is here to help you.
Related Products
Discover similar products that might interest you
Ready to Talk About This Product?
Tell us what you need—from pricing and availability to technical specs or project planning. Our product team will respond within 24 hours.
- Request tailored quotations and lead times
- Get engineering support and compatibility checks
- Receive product literature and case studies
Merci ! Nous avons bien reçu votre demande.
Our product specialists will reach out within 24 hours. A detailed Thank You page has opened in a new tab.